Omai Full-automatic Blood Pres 点击展开
Omai Blood Glucose Meter Serie 点击展开
Omai Hearing Aids Series 点击展开
Omai Infrared Ear Thermometer 点击展开
Omai Digital Thermometer Serie 点击展开
Omai Low & Medium-frequency Tr 点击展开
Omai Cervical and Lumbar Rehab 点击展开
Omai Powerful Protective Appar 点击展开
Omai Self-heating Protective A 点击展开
Omai Medical Fixation Belt Ser 点击展开
Omai Hernia Bandages Series 点击展开
Omai Patch Series 点击展开
Omai Urine Collector Series 点击展开
Omai Back Correction Tape Seri 点击展开
Omai Hand-held Sputum Suction 点击展开
Omai Cervical Traction Apparat 点击展开
Omai Ashi Cupping Device Serie 点击展开
Omai Ashi Red Cupping Device S 点击展开
Omai Glass Cupping Series 点击展开
Omai Adhesive Bandage Series 点击展开
Omai Healthy Foot Spa Machine 点击展开
Omai Kneading Masseur Series 点击展开
Omai Massage Stick Series 点击展开
Omai Foot Massage Shoes Series 点击展开
Omai Health Care Pillow Series 点击展开
Omai Radiation-proof Maternity 点击展开
Omai Medical Oxygen Bag Series 点击展开
Omai Family-use Medicine Chest 点击展开
Omai Full-automatic Pot for De 点击展开
Omai Portable Walking Stick Se 点击展开
Omai Toilet Walker Series 点击展开
Omai Healthy Wheelchair Series 点击展开
 
  Navigation:Home >> Products >> Omai Full-automatic Blood Pres >>
Electronic Sphygmomanometer
Class:Omai Full-automatic Blood Pres 
Brand:OMAI
Name:Electronic Sphygmomanometer
No.:OM-XY02
Status:Phonetic Form
For the medical department and family to measure blood pressure and pulse rate.

1.Voice prompt operations
2.Automatic intelligent pressure
3.Arrhythmia detection
4.Memory function in 65 pairs
5.Can display the time and date
6.Automatic shutdown after measuring
7.Core manufacturing, performance is remarkable

1.Blood pressure measurement range:(40~280)mmHg
2.Heart rate measurement range:30 counts/minute~180 counts/minute
3.Precision pressure:±5mmHg
4.Precision pulse count:within ±5%
5.Resolving Power:BP 0.13Kpa/1mmHg HR one time
6.Suitable Power:DC3V AAA (No7) 2batteries
7.Suitable for wrist circumference:About 13.5cm19.5cm
8.Shape dimension (hosts): 72mmLong×60mmHeight×29mmThick

1.Load batteries:Unload the cover, according to the instructions are negative direction on two (7) alkaline batteries, install battery cover.

2.Tie wristbands:
(1)Palm and sphygmomanometer upward, and at the bottom edge of 1.5 cm distance palm ,tie the band. (wristbands cannot bind tightly, also cannot too loose, with the wrist and comfortable as standard.)
(2)When measuring the position: Relax before measurement for 5-10 minutes, sit down at the tableplace the arm on the table, make wristband at the same hight with heart. Keep quiet and don't talk when measuring.

3.Measure:
(1)When measuring must keep quiet don't shake, speech, smoking, eating to avoid jamming measure.
(2)Turn on the power button, after two seconds, the pressure gauge begin to rise until 180mmHg, numerical gradually declining and measurements.
(3)After measuring the air inside automatic apocatharsis wristbands, blood pressure and pulse display.
(4)The instrument will say "abnormal" at the following situation:
First,the systolic pressure value is more than 140 or lower than 90.Second,the diastolic pressure value is more than 90 or lower than 60.Or else,it says "normal".
(5)Measuring instrument can store value up to 65 groups.
(6)After measuring,if screen shows heart symbol, heart rate is normal.Or else, if heart symbol is put in bracket,it is abnormal.
(7)If you forget to turn off the power,the instrument will automatic shutdown.

4.Adjust date:
(1)In shutdown, long press “set key” 3 seconds into the date "year".
(2)In time set mode, press "power" is up, press "memory key” is down.
(3)Press “set key”, convert month, day, and points.
(4)After adjusting time"minute”, once again pressure return to standby.

5.Memory read and delete:
(1).In the shutdown, press "memory key" can read recent measured values, including: time, date, high pressure, low pressure and heart rate.
(2).Continue to press "memory" button, you can inquiry memory value up to 65 groups.
(3).After display memory continuous pressing "memory" key about 3 seconds will delete all memory value.

1.When not fasten belt ring, please don't open open key.
2.In the measurement, keep the band at the same hight with heart.
3.In the measurement , keep quiet, do not move or talk.
4.When the air caused any discomfort, bind band to press the button immediately, shut off the power.
5.If blood pressure to 300mmHg above, but there is no automatic vent, please solution under belt.
6.Can use wet cloth or a neutral detergent clean body, and dry it, don’t use volatile solvent.
7.Avoid fell, remove or modified sphygmomanometer and belt.
8.Don't distort, tearing belt.
9.Don't put in direct sunlight, humid and dust.
10.If long time don't use instrument, remove batteries.

Print | Close
Home | Company Profiles | Products | News | Video | Service | Guestbook | Recruitment | Contact Us | Set Homepage | Add Favorite
Copyright © 2009-2010 Jinan Omai Pulse Medical Treatment Instrument Co., Ltd.
All Rights Reserved. Support by Xseega